Difference between revisions of "01271"

From Ross-Tech Wiki
(No difference)

Revision as of 12:53, 3 June 2007

01271 - Positioning Motor for Temperature Flap (V68)

01271 - Positioning Motor for Temperature Flap (V68): Faulty

Possible Causes

  • Wiring/Connectors from/to Positioning Motor for Temperature Flap (V68) falty
  • Positioning Motor for Temperature Flap (V68) blocked
  • Positioning Motor for Temperature Flap (V68) faulty

Possible Solutions

  • Check Positioning Motor for Temperature Flap (V68)
    • See Measuring Value Blocks (MVB)
    • Perform Output Test
    • Perform Basic Setting
  • Check/Repair Wiring and Connectors