01370 - Alarm triggered by Interior Monitoring

Possible Causes

  • Anti-Theft Alarm triggered by Signal from Ultrasonic Sensor Control Module (J347)
  • Ultrasonic Sensor Control Module (J347) faulty
  • Wiring/Connectors from/to Ultrasonic Sensor Control Module (J347) faulty
  • False Alarm

Possible Solutions

  • Check/Clear Fault Codes
  • Check Ultrasonic Sensor Control Module (J347)
  • Check Wiring/Connectors from/to Ultrasonic Sensor Control Module (J347)

Special Notes

  • This fault code is only a note.