Difference between revisions of "01577"

From Ross-Tech Wiki
(Created page with "__FORCETOC__ == 01577 - Turn-Off due to Over-Temp: Upper Limit Exceeded == ==== Possible Symptoms ==== * Air Ride Suspension bleeds down ==== Possible Causes ==== * Air l...")
 
(No difference)

Latest revision as of 15:37, 4 June 2012


01577 - Turn-Off due to Over-Temp: Upper Limit Exceeded

Possible Symptoms

  • Air Ride Suspension bleeds down

Possible Causes

  • Air leak in Air Ride Suspension System

Possible Solutions

  • Locate and repair air leak

Special Notes

  • On vehicles with Air Ride Suspension, a leak in the system will cause the Air Compressor Motor to run too long and flag this code.
  • This code can also be flagged in other control modules, Headlight Range Control for example. In these cases, it can be a failed motor or mechanical binding.