Difference between revisions of "17072/P0688/001672"

From Ross-Tech Wiki
 
m
Line 1: Line 1:
 
__FORCETOC__
 
__FORCETOC__
== 17072/P0688/001672 - abc ==
+
== 17072/P0688/001672 - ECM Power Relay Load Circuit: (J271): Open Circuit ==
  
 
==== Possible Symptoms ====
 
==== Possible Symptoms ====

Revision as of 09:32, 13 February 2007

17072/P0688/001672 - ECM Power Relay Load Circuit: (J271): Open Circuit

Possible Symptoms

  • Engine Coolant Fan running at full Speed while Ignition is OFF and Engine is COLD (could lead to discharged Battery)

Possible Causes

  • Fuse(s) faulty
  • Power Supply Relay for Engine Control Module (J271) faulty
    • Terminal 87 faulty/hanging
  • Wiring between Engine Control Module (J220) and Power Supply Relay for Engine Control Module (J271) faulty

Possible Solutions

  • Check/Replace Power Supply Relay for Engine Control Module (J271)
  • Check Wiring between Engine Control Module (J220) and Power Supply Relay for Engine Control Module (J271)
  • Check/Replace Engine Control Module (J220)