17950/P1542/005442
From Ross-Tech Wiki
Revision as of 17:21, 17 March 2008 by RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 17950/P1542/005442 - Angle Sensor 1 for Throttle Actuator (G187): Implausible Signal == ==== Possible Symptoms ==== * Malfunction Indicator Lamp (MIL) active ==== Possib...)
17950/P1542/005442 - Angle Sensor 1 for Throttle Actuator (G187): Implausible Signal
Possible Symptoms
- Malfunction Indicator Lamp (MIL) active
Possible Causes
- Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty
- Power Supply for Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty
- Wiring/Connector(s) from/to Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty
Possible Solutions
- Check Angle Sensors 1/2 for Throttle Actuator (G187/G188)
- See Measuring Value Blocks (MVB), usually MVB 062
- Power Supply for Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty
- Wiring/Connector(s) from/to Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty