Difference between revisions of "18021/P1613/005651"

From Ross-Tech Wiki
m
Line 11: Line 11:
 
* Wiring/Connectors from/to Malfunction Indicator Lamp (MIL) faulty
 
* Wiring/Connectors from/to Malfunction Indicator Lamp (MIL) faulty
 
* Control Module Cording incorrect
 
* Control Module Cording incorrect
 +
* Heavy wear on ignition/starter switch (D) contacts
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====

Revision as of 09:30, 4 May 2012

18021/P1613/005651 - MIL Control Circuit: Open or Short to Plus

Possible Symptoms

  • Malfunction Indicator Lamp (MIL) not working properly

Possible Causes

  • Malfunction Indicator Lamp (MIL) faulty
  • Wiring/Connectors from/to Malfunction Indicator Lamp (MIL) faulty
  • Control Module Cording incorrect
  • Heavy wear on ignition/starter switch (D) contacts

Possible Solutions

  • Check Malfunction Indicator Lamp (MIL)
  • Check Wiring/Connectors from/to Malfunction Indicator Lamp (MIL)
  • Check Control Module Coding