Audi A4 (8E) Automatic Roof

From Ross-Tech Wiki

Adaptation

Channel 01: Reset

Prerequisites:

  • Automatic Roof closed
  • Measuring Value Blocks (MVB) OK

To reset the switch positions, save a new value of 1.

Special Notes

  • If Adaptation will not set with only the 02000 fault present, check TSB 61-08-05 (2010940, NAR only)


Measuring Block Data

Reading Roof Electronics Switch Conditions, Electric Power Top Closed

Measuring Block Group 001 (Roof Closed)
Field 2 X Field 3 Data
1 1 0 1 1 0 1 0 1 0 X 1 0 1 0 F201
F290
F293
F200
X
Not used, always "0"
F292
X
F171
F202
F294
F295
F172
Switch Point for Bow UP
Switch Point for Bow OPEN
Switch Point for Bow DEAD CENTER


Reading Roof Electronics Switch Conditions, Electric Power Top Opened

Measuring Block Group 001 (Roof Opened)
Field 2 X Field 3 Data
0 0 1 0 1 0 0 1 1 0 X 1 0 1 0 F201
F290
F293
F200
X
Not used, always "0"
F292
X
F171
F202
F294
F295
F172
Switch Point for Bow UP
Switch Point for Bow OPEN
Switch Point for Bow DEAD CENTER