Difference between revisions of "Audi Q7 (4L) Brake Electronics"

From Ross-Tech Wiki
m
 
Line 30: Line 30:
 
After a successful basic setting, field 2 should say "OK".<br>
 
After a successful basic setting, field 2 should say "OK".<br>
 
'''[Done, Go Back]'''<br>
 
'''[Done, Go Back]'''<br>
To make sure the basic setting was succesful, check the sensor again.<br>
+
To make sure the basic setting was successful, check the sensor again.<br>
 
'''[Measuring Blocks - 08]'''<br>
 
'''[Measuring Blocks - 08]'''<br>
 
Group 004<br>
 
Group 004<br>
Line 37: Line 37:
 
'''[Done, Go Back]'''<br>
 
'''[Done, Go Back]'''<br>
 
'''[Close Controller, Go Back - 06]'''<br>
 
'''[Close Controller, Go Back - 06]'''<br>
 +
 +
 +
=== Lateral Acceleration Sensor (G200) ===
 +
 +
'''<u>Prerequisites:</u>'''<br>
 +
* System voltage at least 12.0 V.<br><br>
 +
 +
'''[Select]'''<br>
 +
'''[03 - Brake Electronics]'''<br>
 +
'''[Measuring Blocks - 08]'''<br>
 +
Group 004<br>
 +
'''[Go!]'''<br>
 +
Check field 2, the value has to be between -1.5 and +1.5 m/s².<br>
 +
'''[Done, Go Back]'''<br>
 +
'''[Security Access - 16]'''<br>
 +
Enter 40168, to enable the basic setting.<br>
 +
'''[Do it!]'''<br>
 +
'''[Basic Settings - 04]'''<br>
 +
Group 063<br>
 +
'''[Go!]'''<br>
 +
Activate the Basic Setting.<br>
 +
'''[ON/OFF/Next]'''<br>
 +
After a successful basic setting, field 2 should say "OK".<br>
 +
'''[Done, Go Back]'''<br>
 +
To make sure the basic setting was successful, check the sensor again.<br>
 +
'''[Measuring Blocks - 08]'''<br>
 +
Group 004<br>
 +
'''[Go!]'''<br>
 +
Check field 2, the value has to be between -1.5 and +1.5 m/s².<br>
 +
'''[Done, Go Back]'''<br>
 +
'''[Close Controller, Go Back - 06]'''<br><br><br>
 +
 +
 +
=== Brake Pressure Sensor 1 (G201) ===
 +
 +
'''<u>Prerequisites:</u>'''<br>
 +
* System voltage at least 12.0 V.<br><br>
 +
 +
'''[Select]'''<br>
 +
'''[03 - Brake Electronics]'''<br>
 +
'''[Measuring Blocks - 08]'''<br>
 +
Group 005<br>
 +
'''[Go!]'''<br>
 +
Check field 1, the value has to be between -7.0 and +7.0 bar.<br>
 +
'''[Done, Go Back]'''<br>
 +
'''[Security Access - 16]'''<br>
 +
Enter 40168, to enable the basic setting.<br>
 +
'''[Do it!]'''<br>
 +
'''[Basic Settings - 04]'''<br>
 +
Group 066<br>
 +
'''[Go!]'''<br>
 +
Activate the Basic Setting.<br>
 +
'''[ON/OFF/Next]'''<br>
 +
After a successful basic setting, field 2 should say "OK".<br>
 +
'''[Done, Go Back]'''<br>
 +
To make sure the basic setting was successful, check the sensor again.<br>
 +
'''[Measuring Blocks - 08]'''<br>
 +
Group 005<br>
 +
'''[Go!]'''<br>
 +
Check field 1, the value has to be between -7.0 and +7.0 bar.<br>
 +
'''[Done, Go Back]'''<br>
 +
'''[Close Controller, Go Back - 06]'''<br><br><br>
 +
 +
 +
=== Longitudinal Acceleration Sensor (G251) ===
 +
 +
'''<u>Prerequisites:</u>'''<br>
 +
* System voltage at least 12.0 V.<br><br>
 +
 +
'''[Select]'''<br>
 +
'''[03 - Brake Electronics]'''<br>
 +
'''[Measuring Blocks - 08]'''<br>
 +
Group 006<br>
 +
'''[Go!]'''<br>
 +
Check field 1, the value has to be between -1.5 and +1.5 m/s².<br>
 +
'''[Done, Go Back]'''<br>
 +
'''[Security Access - 16]'''<br>
 +
Enter 40168, to enable the basic setting.<br>
 +
'''[Do it!]'''<br>
 +
'''[Basic Settings - 04]'''<br>
 +
Group 069<br>
 +
'''[Go!]'''<br>
 +
Activate the Basic Setting.<br>
 +
'''[ON/OFF/Next]'''<br>
 +
After a successful basic setting, field 2 should say "OK".<br>
 +
'''[Done, Go Back]'''<br>
 +
To make sure the basic setting was successful, check the sensor again.<br>
 +
'''[Measuring Blocks - 08]'''<br>
 +
Group 006<br>
 +
'''[Go!]'''<br>
 +
Check field 1, the value has to be between -1.5 and +1.5 m/s².<br>
 +
'''[Done, Go Back]'''<br>
 +
'''[Close Controller, Go Back - 06]'''<br>
 +
 +
 +
== Special Procedures ==
 +
 +
=== System Function Test ===
 +
 +
See [[ESP System Function Test (Conti/Teves)|System Function Test]]

Latest revision as of 23:58, 18 February 2012

Coding

If the old Control Module is still accessible read/copy it's Coding to the new Module. In case this is not possible please contact us directly and we will assist you with the Coding Process.

Every inquiry on this topic has to include a full Auto-Scan as well as which parts have been replaced and why, also make sure the Auto-Scan includes the complete VIN of the vehicle in question.



Basic Setting

Sensor for Steering Angle (G85)

Prerequisites:

  • Start the vehicle.
  • Turn the steering wheel one turn to the right and one turn to the left.
  • Drive in a short distance straight line on a level surface at a speed not higher than 20 km/h.
  • If the steering wheel is straight during the test drive then stop the vehicle with the wheels pointed straight.
  • Ensure that the steering wheel is not moved again.
  • Keep the engine running and do not switch off the ignition.
  • System voltage at least 12.0 V

[Select]
[03 - Brake Electronics]
[Security Access - 16]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 060
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was successful, check the sensor again.
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 1, the value has to be between -1.5 and +1.5 °.
[Done, Go Back]
[Close Controller, Go Back - 06]


Lateral Acceleration Sensor (G200)

Prerequisites:

  • System voltage at least 12.0 V.

[Select]
[03 - Brake Electronics]
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 2, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Security Access - 16]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 063
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was successful, check the sensor again.
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 2, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Close Controller, Go Back - 06]



Brake Pressure Sensor 1 (G201)

Prerequisites:

  • System voltage at least 12.0 V.

[Select]
[03 - Brake Electronics]
[Measuring Blocks - 08]
Group 005
[Go!]
Check field 1, the value has to be between -7.0 and +7.0 bar.
[Done, Go Back]
[Security Access - 16]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 066
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was successful, check the sensor again.
[Measuring Blocks - 08]
Group 005
[Go!]
Check field 1, the value has to be between -7.0 and +7.0 bar.
[Done, Go Back]
[Close Controller, Go Back - 06]



Longitudinal Acceleration Sensor (G251)

Prerequisites:

  • System voltage at least 12.0 V.

[Select]
[03 - Brake Electronics]
[Measuring Blocks - 08]
Group 006
[Go!]
Check field 1, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Security Access - 16]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 069
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was successful, check the sensor again.
[Measuring Blocks - 08]
Group 006
[Go!]
Check field 1, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Close Controller, Go Back - 06]


Special Procedures

System Function Test

See System Function Test