C1046/020550

From Ross-Tech Wiki
Revision as of 14:03, 5 December 2023 by Peter (talk | contribs) (Created page with "__FORCETOC__ == C1046/020550 - Ride-Height System; Plausibility Error == ==== Possible Symptoms ==== * Lever Control dash warning * Ride height drops or does not respond ==...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

C1046/020550 - Ride-Height System; Plausibility Error

Possible Symptoms

  • Lever Control dash warning
  • Ride height drops or does not respond

Possible Causes

  • Air Leak (Air struts, lines, fittings, etc.)
  • Weak compressor (not enough air pressure)
  • Valve Block (water damage, stuck valves, etc.)
  • Level Sensors (loose, installed backwards, etc.)

Possible Solutions

  • Check for and repair as needed any Air Leaks
  • Verify compressor operation with Output Tests
  • Verify Valve Block solenoids operation with Output Tests
  • Check Level Sensor plausibility using Measuring Values

Special Notes

  • The fault code C1046 will set if the Level Control module detects instances of uncontrolled height changes (such as due to leakage) or when the height remains unchanged despite a control request.