Difference between revisions of "P189C/006300"

From Ross-Tech Wiki
(Created page with "__FORCETOC__ == 006300-Function Restriction due to Insufficient Pressure Build-Up == === P189C/006300 - 006300-Function Restriction due to Insufficient Pressure Build-Up ===...")
 
Line 20: Line 20:
 
* Check/repair/replace faulty wiring/connections.
 
* Check/repair/replace faulty wiring/connections.
 
* Check/replace faulty fuse(s).
 
* Check/replace faulty fuse(s).
* Replace Mechatronic Unit.
+
* Replace faulty Mechatronic Unit.
  
 
==== Special Notes ====
 
==== Special Notes ====
  
 
*  On the Seven speed AG7-DSG transmission check for battery power at Pin 9 of the 25-Pin connector.
 
*  On the Seven speed AG7-DSG transmission check for battery power at Pin 9 of the 25-Pin connector.
*  Once an effective repair has been completed, faults should be cleared and Basic Settings should be completed.
+
*  Once an effective repair has been completed, clear faults from Transmission Control Module and set Basic Settings.
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 20:46, 25 June 2012

006300-Function Restriction due to Insufficient Pressure Build-Up

P189C/006300 - 006300-Function Restriction due to Insufficient Pressure Build-Up

Possible Symptoms

  • Unable to complete Basic Settings, fault will not clear from Transmission Control Module.

Possible Causes

  • Faulty wiring.
  • Faulty connections.
  • Faulty Fuse(s).
  • Faulty Mechatronic Unit, (V401-Hydraulic pump motor)


Possible Solutions

  • Check/repair/replace faulty wiring/connections.
  • Check/replace faulty fuse(s).
  • Replace faulty Mechatronic Unit.

Special Notes

  • On the Seven speed AG7-DSG transmission check for battery power at Pin 9 of the 25-Pin connector.
  • Once an effective repair has been completed, clear faults from Transmission Control Module and set Basic Settings.