Difference between revisions of "Readiness - APB Engine Code"

From Ross-Tech Wiki
Line 22: Line 22:
 
'''[Go]'''<br>
 
'''[Go]'''<br>
 
'''[Switch to basic settings]'''<br>
 
'''[Switch to basic settings]'''<br>
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the display reads ADP OK.<br>
+
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.<br>
 
'''[Switch to Meas. Blocks]'''<br>
 
'''[Switch to Meas. Blocks]'''<br>
  
Line 31: Line 31:
 
'''[Go]'''<br>
 
'''[Go]'''<br>
 
'''[Switch to basic settings]'''<br>
 
'''[Switch to basic settings]'''<br>
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the display reads ADP OK.<br>
+
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.<br>
 
'''[Switch to Meas. Blocks]'''<br>
 
'''[Switch to Meas. Blocks]'''<br>
  
Line 48: Line 48:
 
'''[01 - Engine]'''<br>
 
'''[01 - Engine]'''<br>
 
'''[Measuring Blocks - 08]'''<br>
 
'''[Measuring Blocks - 08]'''<br>
Select group 063<br>
+
Select group 071<br>
 
'''[Go]'''<br>
 
'''[Go]'''<br>
 
'''[Switch to basic settings]'''<br>
 
'''[Switch to basic settings]'''<br>
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the display reads ADP OK.<br>
+
Leave it in Basic Settings until the fourth field reads Syst.OK<br>
 
'''[Switch to Meas. Blocks]'''<br>
 
'''[Switch to Meas. Blocks]'''<br>
  
 +
 +
''Evap purge test''<br>
 +
 +
Select group 071<br>
 +
'''[Go]'''<br>
 +
'''[Switch to basic settings]'''<br>
 +
Leave it in Basic Settings until the fourth field reads Syst.OK<br>
 +
'''[Switch to Meas. Blocks]'''<br>
  
  

Revision as of 15:35, 5 October 2006

Manually Generating Readiness

  • Ignition ON and Engine OFF


Reading and clearing fault codes

[Select]
[01 - Engine]
[Fault Codes - 02]
[Clear Codes -05]
[Done, Go Back]


Throttle Body Alignment

[Measuring Blocks - 08]
Select group 060
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]


Transmission kickdown (applies to Auto Trans vehicles only!)

Select group 063
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]


[Done, Go Back]
[Close Controller, Go Back]


  • Ignition ON and Engine ON at idle


Fuel leakage test

[Select]
[01 - Engine]
[Measuring Blocks - 08]
Select group 071
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]


Evap purge test

Select group 071
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]


Channel 000
[Read]
[Save]
[Done, Go Back]
[Measuring Blocks - 08]
Block 010 (in 1st Row)
Block 011 (in 2nd Row)
[Go!]
Check fields 2, specification is ADP OK.

  • Move the selector lever in position D and drive with partial load 20 m / 70 ft forward, then brake to standstill.
  • Hold the brake for 10 seconds.
  • Move the selector lever in position R and drive with partial load 20 m / 70 ft reverse, then brake to standstill.
  • Hold the brake for 10 seconds.

The procedure needs to be repeated at least 5 times and can be repeated up to 10 times until the measuring values show ADP OK.
[Done, Go Back]
[Close Controller, Go Back - 06]