Coding

Coding for this Control Module is normally done via Software Version Management (SVM). If the old Control Module is still accessible read/copy it's Coding to the new Module. In case this is not possible please contact us directly and we will assist you with the Coding Process.

Every inquiry on this topic has to include a full Auto-Scan as well as which parts have been replaced and why, also make sure the Auto-Scan includes the complete VIN of the vehicle in question.

Security Access

VCDS will provide this Information specific to the Control Module once you open the Security Access Function.

Basic Setting

Basic Setting for Hydraulic Unit Intake Valves

Basic Setting for Hydraulic Unit Valves The Basic Setting procedure for the Intake and Disconnect valves is only to be done when the ABS module is replaced and fault code 00003 - Control Module: No or Incorrect Basic Setting / Adaptation is present.

Prerequisites:

  • The pump temp must be below 27°C / 80°F. It may be necessary to use a fan with the hood open to keep the temp. down.
  • The engine should be running due to the high brake fluid pressures required to complete the test.

Note: Both the Basic Setting for Hydraulic Unit Intake Valves and Basic Setting for Hydraulic Unit Disconnecting Valves need to be performed in that order.


[Select]
[03 - Brake Electronics]
[Security Access - 16]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 025
[Go!]
Calibration Input Values will be displayed.
Activate the Basic Setting.
[ON/OFF/Next]

  • The control module will display the required pressure range in brackets.
  • If Imp. VL [116/129] >000< Press Pedal 005 is displayed, press the pedal until the actual reading is within 116 ~ 129 and maintain that pressure until [000/000] is shown.
  • Release pedal and wait until the next requested pressure set is shown.
  • Repeat the procedure until No Valv [000/000]>000< Calibrated is shown.

De-Activate the Basic Setting.
[ON/OFF/Next]
Proceed to Basic Setting for Hydraulic Unit Disconnecting Valves


Basic Setting for Hydraulic Unit Disconnecting Valves

[Security Access - 16]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 026
[Go!]
Calibration MCI Values will be displayed.
Activate the Basic Setting.
[ON/OFF/Next]

  • The control module will display the required pressure range in brackets.
  • If MCI pri [096/103] >000< Press Pedal 005 is displayed, press the pedal until the actual reading is within 096 ~ 103 and maintain that pressure until [000/000] is shown.
  • Release pedal and wait until the next requested pressure set is shown.
  • Repeat the procedure until No Valv [000/000] >000< Calibrated is shown.

De-Activate the Basic Setting.
[ON/OFF/Next]


Replacement

After Replacing this Control Module these Steps have to be performed:

If the (old) Hydraulics Unit is still installed these Steps may have to be performed as well: