VW Radio Systems Generation 6

From Ross-Tech Wiki
Revision as of 12:14, 27 March 2008 by RtWiKiSyS0p (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Coding

  • 00?xxxx: Treble Speaker Monitoring
    • 1 = Front and Rear Monitoring inactive
    • 2 = Front Monitoring active / Rear Monitoring inactive
    • 3 = Front Monitoring inactive / Rear Monitoring active
    • 4 = Front and Rear Monitoring active
  • 00x?xxx: Radio Configuration I
    • +2 = CAN-Telephone Control
  • 00xx?xx: Speaker Channels
    • 0 = No passive Speakers (Sound System)
    • 2 = 2 passive Speakers Front and 0 passive Speakers Rear
    • 4 = 4 passive Speakers
  • 00xxx?x: Sound System Correction
    • 0 = No Sound System (No Correction)
    • 1 = Sound System with Cloth Interior (with Open Circuit Recognition)
    • 2 = Sound System with Leather Interior (with Open Circuit Recognition)
    • 3 = Sound System with Cloth Interior (without Open Circuit Recognition)
  • 00xxxx?: Radio Configuration II
    • +1 = Active/Remote Supplied Antenna
    • +2 = CD-Changer/iPod-Connection
    • +4 = CAN-Secondary Display (Board Computer/large Display)


Adaptation

Channel 001: Reception Optimization

This channel allows optimization of the reception behavior for areas with strong FM interference.

  • 0 = Normal reception
  • 1 = Optimized reception

Channel 010: Remote Control

  • 0 = Playback disabled
  • 1 = Playback enabled

Note: After closing the Diagnostic Session/Communication the Standard Value 0 is automatically being restored.

Channel 011: Remote Control (Source)

  • 0 = FM
  • 1 = AM

Note: After closing the Diagnostic Session/Communication the Standard Value 0 is automatically being restored.

Channel 012: Remote Control (Frequency FM)

The Frequency Adjustment is being carried out incrementally starting with 0 = 88.3 MHz.
Note: After closing the Diagnostic Session/Communication the Standard Value 0 is automatically being restored.

Channel 013: Remote Control (Frequency AM)

The Frequency Adjustment is being carried out incrementally starting with 0 = 540 kHz.
Note: After closing the Diagnostic Session/Communication the Standard Value 0 is automatically being restored.

Channel 014: Remote Control (Volume)

  • Range: 0...100
  • Standard: 40

Note: After closing the Diagnostic Session/Communication the Standard Value 0 is automatically being restored.

Channel 015: Remote Control (Balance)

Note: After closing the Diagnostic Session/Communication the Standard Value 0 is automatically being restored.

Channel 016: Remote Control (Fader)

Note: After closing the Diagnostic Session/Communication the Standard Value 0 is automatically being restored.