00264 - Solenoid valve 4 (N91): open circuit / short to ground
Possible Causes
- Open circuit or short circuit in wiring
- (K2 clutch) Malfunctioning solenoid valve 4
Possible Solutions
- Check wiring, connections and solenoid
- Replace N91