1.
01176 - Key Faulty: Signal too Low
- 1.1.1 Possible Causes
- 1.2.1 Possible Solutions
Gerrit Speek (talk | contribs) No edit summary |
(No difference)
|
Revision as of 17:18, 1 August 2006
01176 - Key Faulty: Signal too Low
Possible Causes
- Low voltage in key-battery
- Bad connections between immo reader coil and immo control module
Possible Solutions
- Replace key-battery
- If more than one key acts like this, check / clean the connector between immo reader coil and immo control module, the contacts tend to oxidize
- There is also another known issue with the wiring between reader coil and immo module, they are known to be too short so there is a 'longer' wiring (8D0-972-275) available