01236: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
RtWiKiSyS0p (talk | contribs) No edit summary |
(No difference)
|
Latest revision as of 05:59, 16 March 2007
01236 - Shift Selector Locking Solenoid (N110)
01236 - Shift Selector Locking Solenoid (N110): Open or Short to Ground
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Fuse(s) faulty
- Power Supply for Shift Selector Locking Solenoid (N110) faulty
- Wiring/Connectors from/to Shift Selector Locking Solenoid (N110) faulty
Possible Solutions
- Check/Replace Fuse(s)
- Check/Repair Power Supply for Shift Selector Locking Solenoid (N110)
- Check/Repair Wiring/Connectors from/to Shift Selector Locking Solenoid (N110)