00266: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
Gerrit Speek (talk | contribs) No edit summary |
RtWiKiSyS0p (talk | contribs) No edit summary |
||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
== 00266 - Solenoid | == 00266 - Solenoid Valve 5 (N92) == | ||
=== 00266 - Solenoid Valve 5 (N92): Open or Short to Ground === | |||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
* Open | * Wiring/Connectors from/to Solenoid Valve 5 (N92) Open or Short to Ground | ||
* ( | * Solenoid Valve 5 (N92) faulty | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
* Check | * Check/Repair Wiring/Connectors from/to Solenoid Valve 5 (N92) | ||
* Replace N92 | * Check/Replace Solenoid Valve 5 (N92) | ||
** See Measuring Value Blocks (MVB) | |||
** Perform Output Test | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 09:30, 22 March 2007
00266 - Solenoid Valve 5 (N92)
00266 - Solenoid Valve 5 (N92): Open or Short to Ground
Possible Causes
- Wiring/Connectors from/to Solenoid Valve 5 (N92) Open or Short to Ground
- Solenoid Valve 5 (N92) faulty
Possible Solutions
- Check/Repair Wiring/Connectors from/to Solenoid Valve 5 (N92)
- Check/Replace Solenoid Valve 5 (N92)
- See Measuring Value Blocks (MVB)
- Perform Output Test