== 00266 - Solenoid valve 5 (N92): open circuit / short to ground ==
== 00266 - Solenoid Valve 5 (N92) ==
=== 00266 - Solenoid Valve 5 (N92): Open or Short to Ground ===


==== Possible Causes ====
==== Possible Causes ====


* Open circuit or short circuit in wiring
* Wiring/Connectors from/to Solenoid Valve 5 (N92) Open or Short to Ground
* (B1 break) Malfunctioning solenoid valve 5
* Solenoid Valve 5 (N92) faulty


==== Possible Solutions ====
==== Possible Solutions ====


* Check wiring, connections and solenoid
* Check/Repair Wiring/Connectors from/to Solenoid Valve 5 (N92)
* Replace N92
* Check/Replace Solenoid Valve 5 (N92)
** See Measuring Value Blocks (MVB)
** Perform Output Test


[[Category:Fault Codes]]
[[Category:Fault Codes]]

Revision as of 09:30, 22 March 2007

00266 - Solenoid Valve 5 (N92)

00266 - Solenoid Valve 5 (N92): Open or Short to Ground

Possible Causes

  • Wiring/Connectors from/to Solenoid Valve 5 (N92) Open or Short to Ground
  • Solenoid Valve 5 (N92) faulty

Possible Solutions

  • Check/Repair Wiring/Connectors from/to Solenoid Valve 5 (N92)
  • Check/Replace Solenoid Valve 5 (N92)
    • See Measuring Value Blocks (MVB)
    • Perform Output Test