01375 - Valves for Engine Mounting: Stage 1
01375 - Valves for Engine Mounting: Stage 1: Output won't Switch or Short to B+
Possible Symptoms
- Electro-Hydraulic Engine Mounts permanently hard
Possible Causes
- Valves for Engine Mounting faulty
- Wiring/Connectors from/to Valves for Engine Mounting faulty
Possible Solutions
- Check Valves for Engine Mounting