01809: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
New page: __FORCETOC__ == 01809 - Actuating Motor for Temperature Flap; Left (V158) == === 01800 - Actuating Motor for Temperature Flap; Blocked or No Voltage === ==== Possible Symptoms ==== * HV... |
(No difference)
|
Revision as of 15:13, 26 November 2008
01809 - Actuating Motor for Temperature Flap; Left (V158)
01800 - Actuating Motor for Temperature Flap; Blocked or No Voltage
Possible Symptoms
- HVAC temperature inconsistent.
Possible Causes
- Left Temperature Flap (V158) faulty
- Wiring/Connectors between Left Temperature Flap (V158) and A/C Control Head (E87) faulty
- Temperature flap stuck or obstructed (unable to move freely)
Possible Solutions
- Check Wiring/Connectors between Left Temperature Flap (V158) and A/C Control Head (E87) faulty
- Run Output Tests to make sure Left Temperature Flap (V158) can operate freely.