01049: Difference between revisions

No edit summary
 
No edit summary
Line 1: Line 1:
__FORCETOC__
__FORCETOC__
== 01049 - Supply Voltage Term 50 ==
== 01049 - Supply Voltage Term 50 ==
=== 01049 - Supply Voltage Term 50: Short to Plus ===
==== Possible Causes ====
* Fuse(s) faulty
* Wiring and/or Connector(s) from/to Alternator Relay (J53) faulty
* Alternator Relay (J53) faulty
==== Possible Solutions ====
* Check Fuse(s)
* Check Wiring and/or Connector(s) from/to Alternator Relay (J53)
* Check/Replace Alternator Relay (J53)
==== Special Notes ====
* When found in [[Audi A6/S6/RS6/allroad (4F)|Audi A6 (4F)]]: Access/Start Authorization, check Measuring Value Blocks.


=== 01049 - Supply Voltage Term 50: Electrical Fault in Circuit ===
=== 01049 - Supply Voltage Term 50: Electrical Fault in Circuit ===

Revision as of 09:14, 18 April 2009

01049 - Supply Voltage Term 50

01049 - Supply Voltage Term 50: Short to Plus

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Alternator Relay (J53) faulty
  • Alternator Relay (J53) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Alternator Relay (J53)
  • Check/Replace Alternator Relay (J53)

Special Notes

  • When found in Audi A6 (4F): Access/Start Authorization, check Measuring Value Blocks.


01049 - Supply Voltage Term 50: Electrical Fault in Circuit

Possible Solutions

  • Check Ignition Switch (D) Terminal 50