00603: Difference between revisions
          From Ross-Tech Wiki
          
          
      
      
      
      Table Of Contents
- 
          
          1.
          00603 - Footwell / Defroster Flap Motor (V85)
          
- 
      
      1.1.1
      00603 - Footwell / Defroster Flap Motor (V85): Faulty
      
- 1.1.1.2 Possible Causes
 
- 1.1.2.2 Possible Solutions
 
- 1.1.3.2 Special Notes
 
 
 - 
      
      1.1.1
      00603 - Footwell / Defroster Flap Motor (V85): Faulty
      
 
 Created page with '__FORCETOC__ == 00603 - Footwell / Defroster Flap Motor (V85) ==  === 00603 - Footwell / Defroster Flap Motor (V85): Faulty ===  ==== Possible Causes ====  * Wiring/Connectors fr…'  | 
			
(No difference) 
 | 
Latest revision as of 01:53, 10 June 2010
00603 - Footwell / Defroster Flap Motor (V85)
00603 - Footwell / Defroster Flap Motor (V85): Faulty
Possible Causes
- Wiring/Connectors from/to Footwell / Defroster Flap Motor (V85)
 - Positioning Motor for Footwell / Defroster Flap Motor (V85) blocked
 - Positioning Motor for Footwell / Defroster Flap Motor (V85) faulty
 
Possible Solutions
- Check Footwell / Defroster Flap Motor (V85)
- See Measuring Value Blocks (MVB)
 - Perform Output Test
 - Perform Basic Setting
 
 - Check/Repair Wiring and Connectors
 - Check/Repair Obstructions or Blockage
 
Special Notes
- Common HVAC Basic Settings Group(s) include 000 -or- 001