18045/P1637/005687 - Powertrain Data Bus: Missing Message from Electric Load Controller
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Fuse(s) faulty
- Databus Wiring and/or Connector(s) from/to Central Electronics Control Module (J519) faulty
- Central Electronics Control Module (J519) faulty
Possible Solutions
- Check Fuse(s)
- Check Databus Wiring and/or Connector(s) from/to Central Electronics Control Module (J519)
- Check/Replace Central Electronics Control Module (J519)
- Check Measuring Value Blocks (MVB)