01814: Difference between revisions

Created page with '== 01814 - Supply Voltage for Door Controller; Rear Right (J389) == === 01814 - Supply Voltage for Door Controller; Rear Right (J389): Lower Limit Exceeded === ==== Possible Sy…'
 
mNo edit summary
 
Line 16: Line 16:


* Check Fuse(s)
* Check Fuse(s)
** Check Door Controller Rear Right (J389) Measuring Value Block (MVB)
** Check Door Controller Rear Right (J389) Measuring Value Blocks (MVB)
* Check Wiring and/or Connector(s) from/to Door Controller Rear Right (J389)
* Check Wiring and/or Connector(s) from/to Door Controller Rear Right (J389)


__FORCETOC__
__FORCETOC__
[[Category:Fault Codes]]
[[Category:Fault Codes]]

Latest revision as of 04:06, 5 December 2010

01814 - Supply Voltage for Door Controller; Rear Right (J389)

01814 - Supply Voltage for Door Controller; Rear Right (J389): Lower Limit Exceeded

Possible Symptoms

  • Door Controller Functionality limited
  • Window Regulator not working

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Door Controller Rear Right (J389) faulty

Possible Solutions

  • Check Fuse(s)
    • Check Door Controller Rear Right (J389) Measuring Value Blocks (MVB)
  • Check Wiring and/or Connector(s) from/to Door Controller Rear Right (J389)