P068A/001674 - ECM Power Relay Load Circuit: De-Energized Performance Too Early
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Fuse(s) faulty
- Ignition Switch faulty
- Wiring and/or Connector(s) from/to Power Supply Relay (J271/J317) faulty
- Power Supply Relay (J271/J317) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Power Supply Relay (J271/J317)
- Check/Replace Power Supply Relay (J271/J317)