00532: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
-
1.
00532 - Supply Voltage B+
-
1.1.1
00532 - Supply Voltage B+: Signal too Low
- 1.1.1.2 Possible Causes
- 1.1.2.2 Possible Solutions
- 1.1.3.2 Special Notes
-
1.2.1
00532 - Supply Voltage B+: Upper Limit Exceeded
- 1.2.1.6 Possible Causes
- 1.2.2.6 Possible Solutions
-
1.1.1
00532 - Supply Voltage B+: Signal too Low
RtWiKiSyS0p (talk | contribs) mNo edit summary |
No edit summary |
||
(2 intermediate revisions by one other user not shown) | |||
Line 18: | Line 18: | ||
* When found in an individual control module, it's most likely a local source (e.g. wiring/connectors). | * When found in an individual control module, it's most likely a local source (e.g. wiring/connectors). | ||
* When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator). | * When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator). | ||
* Intermittent codes are often | * Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored. | ||
* Common with [[16946/P0562/001378|16946/P0562/001378 - System Voltage: Too Low]] stored in other control modules. | |||
=== 00532 - Supply Voltage B+: Upper Limit Exceeded === | |||
==== Possible Causes ==== | |||
* Faulty Voltage Regulator | |||
* Power Supply (Battery/Generator) faulty | |||
* Overvoltage from External Sources | |||
==== Possible Solutions ==== | |||
* Check Voltage Regulator | |||
* Check Power Supply (Battery/Generator) | |||
* Discontinue the use of a battery charger or jump-starting the vehicle with an improper voltage source | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 21:28, 4 September 2024
00532 - Supply Voltage B+
00532 - Supply Voltage B+: Signal too Low
Possible Causes
- Wiring/Connectors from/to Control Module faulty
- Power Supply (Battery/Generator) faulty
Possible Solutions
- Check/Repair Wiring/Connectors from/to Control Module
- Check Power Supply (Battery/Generator)
Special Notes
- When found in an individual control module, it's most likely a local source (e.g. wiring/connectors).
- When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
- Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.
- Common with 16946/P0562/001378 - System Voltage: Too Low stored in other control modules.
00532 - Supply Voltage B+: Upper Limit Exceeded
Possible Causes
- Faulty Voltage Regulator
- Power Supply (Battery/Generator) faulty
- Overvoltage from External Sources
Possible Solutions
- Check Voltage Regulator
- Check Power Supply (Battery/Generator)
- Discontinue the use of a battery charger or jump-starting the vehicle with an improper voltage source