16474/P0090/000144 - Valve for Fuel Metering (N290): Open Circuit

Possible Symptoms

  • MIL (Malfunction Indicator Lamp) ON
  • Loss of power (limp mode) possible
  • Difficulty starting engine (extended cranking or no start)
  • Increased emissions
  • DTC stored in ECM


Possible Causes

  • Open circuit in wiring to Valve for Fuel Metering -N290-
  • Faulty Valve for Fuel Metering -N290-
  • Faulty Fuel Pressure Regulator Valve -N276-
  • Poor electrical connections (loose, corroded, or damaged pins)
  • ECM power stage fault


Possible Solutions

  • Check wiring and connectors to Valve for Fuel Metering -N290-
  • Check Fuel Pressure Regulator Valve -N276-
  • Repair or replace wiring/connectors as necessary
  • Replace faulty Valve for Fuel Metering -N290- or Fuel Pressure Regulator Valve -N276-
  • If no fault is found in wiring or components, suspect ECM internal fault
  • Measure resistance between component connector terminals 1 and 2
    • Specified value: 1.5 – 11 Ω (±0.5 Ω @ ~20 °C) (verify ALL values with official repair information!)


Monitoring Conditions

  • Signal voltage < 4.70 V
  • Power stage = permanently high
  • Duration ≥ 0.20 sec.
  • Continuous / 2 DCY


Special Notes