01206: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
-
1.
01206 - Signal for Duration of Ignition Off Time
- 1.1.1 Possible Causes
- 1.2.1 Possible Solutions
- 1.3.1 Special Notes
RtWiKiSyS0p (talk | contribs) No edit summary |
No edit summary |
||
Line 15: | Line 15: | ||
* Check Instrument Cluster (J285) | * Check Instrument Cluster (J285) | ||
* Check Climatronic Control (J255) | * Check Climatronic Control (J255) | ||
==== Special Notes ==== | |||
* If this fault won't clear with key on, engine off, try clearing it while the engine is running. | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 20:54, 1 September 2023
01206 - Signal for Duration of Ignition Off Time
Possible Causes
- Ignition Switch faulty
- Wiring between Instrument Cluster (J285) and Climatronic Control (J255) faulty
- Instrument Cluster (J285) faulty
- Climatronic Control (J255) faulty
Possible Solutions
- Check Ignition Switch
- Check Wiring between Instrument Cluster (J285) and Climatronic Control (J255)
- Check Instrument Cluster (J285)
- Check Climatronic Control (J255)
Special Notes
- If this fault won't clear with key on, engine off, try clearing it while the engine is running.