== Basic Setting ==
== Basic Setting ==
=== Customer Service Start ===
=== Function Test (Customer Service Start) ===


'''<u>Prerequisites:</u>'''<br>
'''<u>Prerequisites:</u>'''<br>

Latest revision as of 06:40, 8 October 2007

Coding

Adaptation

Basic Setting

Function Test (Customer Service Start)

Prerequisites:

  • Climate Control OFF
  • Enough Fuel in Fuel Tank (clearly NOT on reserve)
  • Battery charged
  • Coolant Temperature below 60 °C
  • Do NOT disconnect VAG-COM while performing this procedure.

[Select]
[18 - Aux. Heater]
[Basic Settings - 04]
Group 011
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
Observe Field 3, it represents the current status of the system.
[Done, Go Back]
[Close Controller, Go Back - 06]