01813: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
RtWiKiSyS0p (talk | contribs) Created page with '== 01813 - Supply Voltage for Door Controller; Rear Left (J388) == === 01813 - Supply Voltage for Door Controller; Rear Left (J388): Lower Limit Exceeded === ==== Possible Symp…' |
RtWiKiSyS0p (talk | contribs) mNo edit summary |
||
Line 5: | Line 5: | ||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== | ||
* Door Controller Functionality | * Door Controller Functionality limited | ||
* Window Regulator not working | * Window Regulator not working | ||
Latest revision as of 04:06, 5 December 2010
01813 - Supply Voltage for Door Controller; Rear Left (J388)
01813 - Supply Voltage for Door Controller; Rear Left (J388): Lower Limit Exceeded
Possible Symptoms
- Door Controller Functionality limited
- Window Regulator not working
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Door Controller Rear Left (J388) faulty
Possible Solutions
- Check Fuse(s)
- Check Door Controller Rear Left (J388) Measuring Value Blocks (MVB)
- Check Wiring and/or Connector(s) from/to Door Controller Rear Left (J388)