Created page with "== 18437/P2005/008197 - Intake Manifold Flap; Bank 2: Stuck Open == ==== Possible Causes ==== * Vacuum leak * Faulty Intake Manifold Runner Position Sensor1 (G512) * Intake ..." |
Sebastian1 (talk | contribs) m Sebastian1 moved page 18437/P2005/008197 - Intake Manifold Flap; Bank 2: Stuck Open to 18437/P2005/008197 |
||
(One intermediate revision by one other user not shown) | |||
Line 15: | Line 15: | ||
** Perform Basic Setting ''(Switch Ignition OFF between Output Test and Basic Setting)'' | ** Perform Basic Setting ''(Switch Ignition OFF between Output Test and Basic Setting)'' | ||
==== Special Notes ==== | |||
* When found in 2012-2016 Audi with 3.0 TFSI, please see TPI 2050329 | |||
** Vacuum operated water pump may draw excessive vacuum causing intake manifold flaps to malfunction. Updated vacuum hose for water pump. | |||
*** https://static.nhtsa.gov/odi/tsbs/2018/MC-10133286-9999.pdf NHTSA | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 12:46, 28 April 2022
18437/P2005/008197 - Intake Manifold Flap; Bank 2: Stuck Open
Possible Causes
- Vacuum leak
- Faulty Intake Manifold Runner Position Sensor1 (G512)
- Intake Manifold Runner binding or sticking
Possible Solutions
- Replaced failed vacuum line
- Check Intake Manifold Runner Position Sensor 2 (G512) and wiring, see repair manual
- Check Intake Manifold Flap
- Use Output Test
- Perform Basic Setting (Switch Ignition OFF between Output Test and Basic Setting)
Special Notes
- When found in 2012-2016 Audi with 3.0 TFSI, please see TPI 2050329
- Vacuum operated water pump may draw excessive vacuum causing intake manifold flaps to malfunction. Updated vacuum hose for water pump.