Revision as of 08:29, 5 May 2007
18237/P1829 - Pressure Control Valve 4 (N218): Open/Short to Ground
Possible Causes
- Wiring from/to Pressure Control Valve 4 (N218) Open/Short to Ground
- Pressure Control Valve 4 (N218) faulty
Possible Solutions
- Check Wiring from/to Pressure Control Valve 4 (N218)
- Check Pressure Control Valve 4 (N218)
- Check Measuring Blocks
Special Notes
- Pressure Control Valve 4 (N218) might be referred to as Solenoid Valve 7 (N94)
- Start with checking connectors for corrosion or water damage, in case of 01V transmission pay special attention to 16-pin connector between valve body and wiring harness.
 
 
      