01813: Difference between revisions

Created page with '== 01813 - Supply Voltage for Door Controller; Rear Left (J388) == === 01813 - Supply Voltage for Door Controller; Rear Left (J388): Lower Limit Exceeded === ==== Possible Symp…'
 
mNo edit summary
 
Line 5: Line 5:
==== Possible Symptoms ====
==== Possible Symptoms ====


* Door Controller Functionality
* Door Controller Functionality limited
* Window Regulator not working
* Window Regulator not working



Latest revision as of 04:06, 5 December 2010

01813 - Supply Voltage for Door Controller; Rear Left (J388)

01813 - Supply Voltage for Door Controller; Rear Left (J388): Lower Limit Exceeded

Possible Symptoms

  • Door Controller Functionality limited
  • Window Regulator not working

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Door Controller Rear Left (J388) faulty

Possible Solutions

  • Check Fuse(s)
    • Check Door Controller Rear Left (J388) Measuring Value Blocks (MVB)
  • Check Wiring and/or Connector(s) from/to Door Controller Rear Left (J388)