01549: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
RtWiKiSyS0p (talk | contribs) Created page with '== 01549 - Supply Voltage for Parking Aid Sensor == === 01549 - Supply Voltage for Parking Aid Sensor: Short to Ground === ==== Possible Symptoms ==== * Malfunction Indicator …' |
RtWiKiSyS0p (talk | contribs) mNo edit summary |
||
Line 19: | Line 19: | ||
* Check Wiring and/or Connector(s) from/to Parking Aid Sensor(s) | * Check Wiring and/or Connector(s) from/to Parking Aid Sensor(s) | ||
* Check/Replace Parking Aid Sensor(s) | * Check/Replace Parking Aid Sensor(s) | ||
** Check Measuring Value Block(s) for Supply Voltage | |||
__FORCETOC__ | __FORCETOC__ | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 13:48, 19 May 2011
01549 - Supply Voltage for Parking Aid Sensor
01549 - Supply Voltage for Parking Aid Sensor: Short to Ground
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
- Parking Aid not working
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Parking Aid Sensor(s) faulty
- Parking Aid Sensor(s) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Parking Aid Sensor(s)
- Check/Replace Parking Aid Sensor(s)
- Check Measuring Value Block(s) for Supply Voltage