00771 - Fuel Level Sensor (G)
00771 - Fuel Level Sensor (G): Open / Short Circuit to B+
Possible Symptoms
- Fuel reserve displayed value 0 (empty)
Possible Causes
- Wiring between Fuel Level Sensor (G) and Instrument Cluster: Open or Short Circuit
Possible Solutions
- Check wiring between Fuel Level Sensor (G) and Instrument Cluster
- Check Measuring Block Value
00771 - Fuel Level Sensor (G): Short to Ground
Possible Symptoms
- Fuel reserve displayed value 0 (empty)
Possible Causes
- Fuel Level Sensor (G) damaged
Possible Solutions
- Check / Replace Fuel Level Sensor (G)