Latest revision as of 02:53, 4 March 2011

17819/P1411/005137 - Secondary Air Injection System; Bank 2: Insufficient Flow

Possible Symptoms

  • Malfunction Indicator Light (MIL) active

Possible Causes

  • Fuse for Secondary Air Injection Pump blown
  • Vacuum Hose(s) leaky or collapsed
  • Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve leaking
  • Secondary Air Injection Solenoid(s) faulty
  • Combi Valve(s) faulty

Possible Solutions

  • Check Fuse for Secondary Air Injection Pump
  • Check Vacuum Hose(s)
  • Check Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve
  • Check Secondary Air Injection Solenoid(s)
  • Check Combi Valve(s)