00229: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
-
1.
00229 - Refrigerant Pressure
-
1.1.1
00229 - Refrigerant Pressure: 001 Upper Limit Exceeded
- 1.1.1.2 Possible Causes
- 1.1.2.2 Possible Solutions
-
1.2.1
00229 - Refrigerant Pressure: 002 Lower Limit Exceeded
- 1.2.1.5 Possible Causes
- 1.2.2.5 Possible Solutions
-
1.1.1
00229 - Refrigerant Pressure: 001 Upper Limit Exceeded
RtWiKiSyS0p (talk | contribs) mNo edit summary |
No edit summary |
||
Line 2: | Line 2: | ||
== 00229 - Refrigerant Pressure == | == 00229 - Refrigerant Pressure == | ||
=== 00229 - Refrigerant Pressure: | === 00229 - Refrigerant Pressure: 001 Upper Limit Exceeded === | ||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
* Refrigerant System | * Refrigerant System overcharged | ||
* Refrigerant | * Cooling Fan(s) are not functioning correctly | ||
* Condenser is dirty or Airflow is restricted or blocked | |||
* Refrigerant System blockage, stuck expansion valve, etc.. | |||
* Refrigerant Pressure Sensor | |||
==== Possible Solutions ==== | |||
* Use a Gauge Set to check Low and High pressures | |||
* Recover and Recharge Refrigerant to proper charge level (refer to vehicle label) | |||
* Check Cooling fans, 'Output Test' with VCDS | |||
* Check Expansion Valve | |||
* Refrigerant Pressure Sensor: | |||
** Check Measuring Value Blocks | |||
** Check wiring, connections | |||
** Check for leak at sensor connector) | |||
=== 00229 - Refrigerant Pressure: 002 Lower Limit Exceeded === | |||
==== Possible Causes ==== | |||
* Refrigerant System undercharged | |||
* Weak compressor / clutch | |||
* Stuck open Expansion Valve | |||
* Refrigerant Pressure Sensor | |||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
* | * Use a Gauge Set to check Low and High pressures | ||
* Check/ | * Recover and Recharge Refrigerant to proper charge level (refer to vehicle label) | ||
* Check Compressor / clutch | |||
* Check Expansion Valve | |||
* Refrigerant Pressure Sensor: | |||
** Check Measuring Value Blocks | |||
** Check wiring, connections | |||
** Check for leak at sensor connector) | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 16:43, 5 June 2017
00229 - Refrigerant Pressure
00229 - Refrigerant Pressure: 001 Upper Limit Exceeded
Possible Causes
- Refrigerant System overcharged
- Cooling Fan(s) are not functioning correctly
- Condenser is dirty or Airflow is restricted or blocked
- Refrigerant System blockage, stuck expansion valve, etc..
- Refrigerant Pressure Sensor
Possible Solutions
- Use a Gauge Set to check Low and High pressures
- Recover and Recharge Refrigerant to proper charge level (refer to vehicle label)
- Check Cooling fans, 'Output Test' with VCDS
- Check Expansion Valve
- Refrigerant Pressure Sensor:
- Check Measuring Value Blocks
- Check wiring, connections
- Check for leak at sensor connector)
00229 - Refrigerant Pressure: 002 Lower Limit Exceeded
Possible Causes
- Refrigerant System undercharged
- Weak compressor / clutch
- Stuck open Expansion Valve
- Refrigerant Pressure Sensor
Possible Solutions
- Use a Gauge Set to check Low and High pressures
- Recover and Recharge Refrigerant to proper charge level (refer to vehicle label)
- Check Compressor / clutch
- Check Expansion Valve
- Refrigerant Pressure Sensor:
- Check Measuring Value Blocks
- Check wiring, connections
- Check for leak at sensor connector)