Bentley Continental (3W) Automatic Roof: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
- 1. Adaptation
Created page with "__FORCETOC__ == Coding == == Adaptation ==" |
No edit summary |
||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
Additional information can be found in the [[Official Factory Repair Information]]. | |||
== Adaptation == | == Adaptation == | ||
'''<u>Prerequisites: End Stops</u>''' | |||
* Vehicle system voltage above 12.0v (Engine running) | |||
* All doors and lids shut | |||
* No faults in the 'Convertible Top' controller | |||
* Convertible Top in good condition, no damage | |||
* Convertible Top Closed and locked | |||
=== Channel 00: Delete End Stops === | |||
To reset the learned End Stops, save a new value of 0 | |||
* Then follow with the Relearn End Stops. | |||
=== Channel 01: Relearn End Stops === | |||
To start the relearn the End Stops, save a new value of 1 | |||
* Open the Convertible Top to 'Relearn' the End Stops. | |||
* Check for and clear any fault codes. | |||
* Check for proper Convertible Top Operation |
Revision as of 16:36, 12 April 2018
Additional information can be found in the Official Factory Repair Information.
Adaptation
Prerequisites: End Stops
- Vehicle system voltage above 12.0v (Engine running)
- All doors and lids shut
- No faults in the 'Convertible Top' controller
- Convertible Top in good condition, no damage
- Convertible Top Closed and locked
Channel 00: Delete End Stops
To reset the learned End Stops, save a new value of 0
- Then follow with the Relearn End Stops.
Channel 01: Relearn End Stops
To start the relearn the End Stops, save a new value of 1
- Open the Convertible Top to 'Relearn' the End Stops.
- Check for and clear any fault codes.
- Check for proper Convertible Top Operation
No categories.