01318
From Ross-Tech Wiki
Table Of Contents
-
1.
01318 - Control Module for Injection Pump (J399)
-
1.1.1
01318 - Control Module for Injection Pump (J399): No Elaboration Available
- 1.1.1.2 Possible Symptoms
- 1.1.2.2 Possible Causes
- 1.1.3.2 Possible Solutions
- 1.1.4.2 Special Notes
-
1.2.1
01318 - Control Module for Injection Pump (J399): No Elaboration Available
- 1.2.1.7 Possible Symptoms
- 1.2.2.7 Possible Causes
- 1.2.3.7 Special Notes
-
1.1.1
01318 - Control Module for Injection Pump (J399): No Elaboration Available
01318 - Control Module for Injection Pump (J399)
01318 - Control Module for Injection Pump (J399): No Elaboration Available
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Wiring and/or Connector(s) from/to Injection Pump (J399) faulty
- Injection Pump (J399) faulty
Possible Solutions
- Check Wiring and/or Connector(s) from/to Injection Pump (J399)
- Check Communication to Injection Pump (J399)
- See Measuring Value Block (MVB) 018
- Check/Replace Injection Pump (J399)
Special Notes
- When found on 2.5l V6 TDI, has a Compression Test been performed? This code may be stored in Combination with a Compression Test even though the Communication is OK.
01318 - Control Module for Injection Pump (J399): No Elaboration Available
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Control Module Software Issue
Special Notes
- When found on 2.5l V6 TDI, contact Ross-Tech for Assistance.