00349 - Solenoid Valve 10 (N283)
-
1.2.1
00349 - Solenoid Valve 10 (N283): Open or Short to Plus
- 1.2.1.3 Possible Symptoms
- 1.2.2.3 Possible Causes
- 1.2.3.3 Possible Solutions
- 1.2.4.3 Special Notes
-
1.2.1
00349 - Solenoid Valve 10 (N283): Open or Short to Plus
00349 - Solenoid Valve 10 (N283)
00349 - Solenoid Valve 10 (N283): Open or Short to Ground
00349 - Solenoid Valve 10 (N283): Open or Short to Plus
Possible Symptoms
- Shifting issues
Possible Causes
- Damaged wiring harness
- Failed Solenoid Valve
- Failed TCM
Possible Solutions
- Ohm test wiring harness
Special Notes
- When found on the 6 speed 09G transmission:
- Solenoid Valve 10 (N283) is also noted as The Pressure Control Valve 6 (N271)