00603
From Ross-Tech Wiki
Table Of Contents
-
1.
00603 - Footwell / Defroster Flap Motor (V85)
-
1.1.1
00603 - Footwell / Defroster Flap Motor (V85): Faulty
- 1.1.1.2 Possible Causes
- 1.1.2.2 Possible Solutions
- 1.1.3.2 Special Notes
-
1.1.1
00603 - Footwell / Defroster Flap Motor (V85): Faulty
00603 - Footwell / Defroster Flap Motor (V85)
00603 - Footwell / Defroster Flap Motor (V85): Faulty
Possible Causes
- Wiring/Connectors from/to Footwell / Defroster Flap Motor (V85)
- Positioning Motor for Footwell / Defroster Flap Motor (V85) blocked
- Positioning Motor for Footwell / Defroster Flap Motor (V85) faulty
Possible Solutions
- Check Footwell / Defroster Flap Motor (V85)
- See Measuring Value Blocks (MVB)
- Perform Output Test
- Perform Basic Setting
- Check/Repair Wiring and Connectors
- Check/Repair Obstructions or Blockage
Special Notes
- Common HVAC Basic Settings Group(s) include 000 -or- 001