00819
From Ross-Tech Wiki
Table Of Contents
-
1.
00819 - High Pressure Sensor (G65)
-
1.1.1
00819 - High Pressure Sensor (G65): Open or Short to Ground
- 1.1.1.2 Possible Causes
- 1.1.2.2 Possible Solutions
-
1.2.1
00819 - High Pressure Sensor (G65): Signal too Low
- 1.2.1.5 Possible Symptoms
- 1.2.2.5 Possible Causes
- 1.2.3.5 Possible Solutions
-
1.1.1
00819 - High Pressure Sensor (G65): Open or Short to Ground
00819 - High Pressure Sensor (G65)
00819 - High Pressure Sensor (G65): Open or Short to Ground
Possible Causes
- Wiring/Connectors from/to High Pressure Sensor (G65) faulty
- High Pressure Sensor (G65) faulty
Possible Solutions
- Check Wiring/Connectors from/to High Pressure Sensor (G65)
- Check High Pressure Sensor (G65)
00819 - High Pressure Sensor (G65): Signal too Low
Possible Symptoms
- Climate Control stuck in ECON Mode
Possible Causes
- Insufficient Refrigerant Pressure
- Wiring/Connectors from/to High Pressure Sensor (G65) faulty
- High Pressure Sensor (G65) faulty
Possible Solutions
- Check Refrigerant Pressure
- Check Measuring Value Blocks (MVB)
- Check Wiring/Connectors from/to High Pressure Sensor (G65)
- Check High Pressure Sensor (G65)