01093
From Ross-Tech Wiki
01093 - Switch for Convertible Top Box Lid; Top (F201): Implausible Signal
Possible Symptoms
- Top not operating
Possible Causes
- Wiring Issue for F201 Switch
- Power supply issue for Convertible Top Hydraulic Pump motor (V118)
- Failed Convertible Top Hydraulic Pump motor (V118)
Possible Solutions
- Fix wiring issue
- Replace Convertible Top Hydraulic Pump motor (V118)
Special Notes
- Run jumper wires from the Convertible Top Hydraulic Pump motor (V118) to outside the car and connect a test light to it, verify test light lights up when trying to open or close the top. If the light does power up, then inspect the motor. If the light does not light up, verify fuse, relays and wiring.
- Some people report that after tapping on the Convertible Top Hydraulic Pump motor (V118) with a small hammer it will start to work again.