01262

From Ross-Tech Wiki

Jump to: navigation, search

Contents

01262 - Solenoid Valve for Boost Pressure Control (N75)

01262 - Solenoid Valve for Boost Pressure Control (N75): Short to Ground

Possible Symptoms

  • Reduced Power Output
    • Overrun Cut-Off until Boost pressure falls to a non-critical level
  • Boost Pressure too High

Possible Causes

  • Wiring from/to Solenoid Valve for Boost Pressure Control (N75) faulty (Short to Ground)
  • Solenoid Valve for Boost Pressure Control (N75) faulty

Possible Solutions

  • Check/Replace Solenoid Valve for Boost Pressure Control (N75)

Special Notes

  • Often seen in combination with 00544 (Maximum Boost Pressure Exceeded).


01262 - Solenoid Valve for Boost Pressure Control (N75): Short to Plus

Possible Symptoms

  • Reduced Power Output
  • Boost Pressure too Low

Possible Causes

  • Wiring from/to Solenoid Valve for Boost Pressure Control (N75) faulty (Short to Plus)
  • Solenoid Valve for Boost Pressure Control (N75) faulty

Possible Solutions

  • Check/Replace Solenoid Valve for Boost Pressure Control (N75)


01262 - Solenoid Valve for Boost Pressure Control (N75): Output Open

Possible Symptoms

  • Reduced Power Output
  • Boost Pressure too Low

Possible Causes

  • Wiring from/to Solenoid Valve for Boost Pressure Control (N75) faulty (Open Circuit)
  • Solenoid Valve for Boost Pressure Control (N75) faulty

Possible Solutions

  • Check/Replace Solenoid Valve for Boost Pressure Control (N75)



Unless otherwise noted, all content on this site is Copyright © 2000-2010 by Ross-Tech LLC. All rights reserved.
"VCDS" is a Registered Trademark of Ross-Tech, LLC.
Ross-Tech is not affiliated with the Volkswagen Group in any way.