01542

From Ross-Tech Wiki

01542 - Yaw Rate Sensor (G202)

01542 - Yaw Rate Sensor (G202): Electrical Fault in Circuit

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
  • Yaw Rate Sensor (G202) faulty
  • ESP-Sensor Unit (G419) faulty

Possible Solutions

  • Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
  • Check Yaw Rate Sensor (G202)
    • Check Measuring Value Block (MVB)
  • Check ESP-Sensor Unit (G419)


01542 - Yaw Rate Sensor (G202): Implausible Signal

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Ground Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
  • Installation Position of Yaw Rate Sensor (G202) incorrect
  • Yaw Rate Sensor (G202) faulty
  • ESP-Sensor Unit (G419) faulty

Possible Solutions

  • Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
  • Check Installation Position of Yaw Rate Sensor (G202)
  • Check Yaw Rate Sensor (G202)
    • Check Measuring Value Block (MVB)
  • Check ESP-Sensor Unit (G419)


01542 - Yaw Rate Sensor (G202): No or Incorrect Basic Setting / Adaptation

Possible Causes

  • Yaw Rate Sensor (G202) Basic Setting lost/not performed

Possible Solutions