02435

From Ross-Tech Wiki

02435 - Supply Voltage for Control Module for Right Channel

02435 - Supply Voltage for Control Module for Right Channel: Open or Short to Ground

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON
  • Electronic Parking Brake not working

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Parking Brake control module faulty
  • Parking Brake control module faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Parking Brake control module
  • Check/Replace Parking Brake control module