17579/P1171/004465
From Ross-Tech Wiki
17579/P1171/004465 - Angle Sensor 2 for Throttle Actuator (G188) Implausible Signal
Possible Symptoms
- Malfunction Indicator Lamp (MIL) active
Possible Causes
- Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty
- Power Supply for Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty
- Wiring/Connector(s) from/to Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty
Possible Solutions
- Check Angle Sensors 1/2 for Throttle Actuator (G187/G188)
- See Measuring Value Blocks (MVB), usually MVB 062
- Power Supply for Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty
- Wiring/Connector(s) from/to Angle Sensors 1/2 for Throttle Actuator (G187/G188) faulty