17927/P1519/005401
From Ross-Tech Wiki
17927/P1519/005401 - Camshaft Adjustment Bank 1: Malfunction
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Fuse(s) faulty
- Camshaft Adjustment Valve Bank 1 (N205) faulty
- Wiring and/or Connector(s) from/to Camshaft Adjustment Valve Bank 1 (N205) faulty
Possible Solutions
- Check Fuse(s)
- Check/Replace Camshaft Adjustment Valve Bank 1 (N205)
- Perform Output Test/Basic Setting
- Check Wiring and/or Connector(s) from/to Camshaft Adjustment Valve Bank 1 (N205)
- Check chain guides of Camshaft Adjuster Unit (N205) for wear