17927/P1519/005401 - Camshaft Adjustment Bank 1: Malfunction

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Fuse(s) faulty
  • Camshaft Adjustment Valve Bank 1 (N205) faulty
  • Wiring and/or Connector(s) from/to Camshaft Adjustment Valve Bank 1 (N205) faulty

Possible Solutions

  • Check Fuse(s)
  • Check/Replace Camshaft Adjustment Valve Bank 1 (N205)
    • Perform Output Test/Basic Setting
  • Check Wiring and/or Connector(s) from/to Camshaft Adjustment Valve Bank 1 (N205)
  • Check chain guides of Camshaft Adjuster Unit (N205) for wear