18058/P1650/005712
          From Ross-Tech Wiki
          
          
      
      
      
      Table Of Contents
18058/P1650/005712 - Powertrain Data Bus: Missing Message from Instrument Cluster
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
 
Possible Causes
- Fuse(s) faulty
 - Databus Wiring and/or Connector(s) from/to Instrument Cluster (J285) faulty
 - Instrument Cluster (J285) faulty
 
Possible Solutions
- Check Fuse(s)
 - Check Databus Wiring and/or Connector(s) from/to Instrument Cluster (J285)
 - Check/Replace Instrument Cluster (J285)
- Check Measuring Value Blocks (MVB)