18058/P1650/005712
From Ross-Tech Wiki
18058/P1650/005712 - Powertrain Data Bus: Missing Message from Instrument Cluster
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Fuse(s) faulty
- Databus Wiring and/or Connector(s) from/to Instrument Cluster (J285) faulty
- Instrument Cluster (J285) faulty
Possible Solutions
- Check Fuse(s)
- Check Databus Wiring and/or Connector(s) from/to Instrument Cluster (J285)
- Check/Replace Instrument Cluster (J285)
- Check Measuring Value Blocks (MVB)