18074/P1666

From Ross-Tech Wiki

18074/P1666 - Valve for Pump - Jet: Cylinder 1 (N240): Electrical Malfunction

Possible Symptoms

  • Irregular rpm

Possible Causes

  • Wiring and/or connections to/from the Valve for Pump Jet
  • Valve for Pump Jet

Possible Solutions

  • Check wiring and Check / Clean all connections
  • Replace the cable-tree to/from all the Valves for Pump Jet
  • Replace Valve for Pump Jet (replace them all !)

Special Notes

  • The ECU checks the Begin of Injection Period (BIP) by sending a very small amount of current (less than 0.0001 A ) through each injector. Because the current is so small, any extra resistance in the wiring due to damage or corrosion can cause this fault. Before replacing injectors, replace the wiring harness first.