18227/P1819

From Ross-Tech Wiki

18227/P1819 - Pressure Control Valve 2 (N216): Open/Short to Ground

Possible Causes

  • Wiring from/to Pressure Control Valve 2 (N216) Open/Short to Ground
  • Pressure Control Valve 2 (N216) faulty

Possible Solutions

  • Check Wiring from/to Pressure Control Valve 2 (N216)
  • Check Pressure Control Valve 2 (N216)
  • Check Measuring Blocks

Special Notes

  • Pressure Control Valve 2 (N216) might be referred to as Solenoid Valve 5 (N92)
  • Start with checking connectors for corrosion or water damage, in case of 01V transmission pay special attention to 16-pin connector between valve body and wiring harness.